Have you checked to see if the valve's diverter spring/stem is damaged? The backwash valve is the valve which is mounted on either the top or side of your filter tank and are specifically used clean sand filters or DE filters. I have a Pentair (Pac Fab) series 2000 DE filter with built in backwash valve that is leaking out the backwash port at a rate of 6 or 7 drops per minute. Multiport Valve Leaks Around The Cover When the cover on your multiport valve leaks, the first thing you should check is your system's pressure. Your IP: 195.38.168.118, Requested URL: www.poolspanews.com/how-to/ultimate-tech-manual/backwash-valve-repair-for-swimming-pools_o, User-Agent: Mozilla/5.0 (Macintosh; Intel Mac OS X 10_15_7) AppleWebKit/537.36 (KHTML, like Gecko) Chrome/103.0.0.0 Safari/537.36. I think I am going to go out and watch my 20 year old valves in operation. A suction leak in the pump can push some DE into the pool via the skimmer or main drain when the pump is turned off. If you have egg type, they have 6 or 8 clamps. I wont go into the details of my return-side plumbing but, suffice it to say, there are two diverter valves (Pentair 2 3-way valves) there. unions glued on 1 12 Ordering Information PRE-PLUMBED VALVES You will get much more visibility by. In this video we. LEAK TRAC 2400 W/WIRELESS TECH ANDERSON. It is being practiced by thousands of pool owners just like you. One thing i can add is a pool contractor just installed a new liner and replaced the sand. My backwash valve has a crack in the side so I need to replace the entire assembly. Backwash Filter Piston and Seals for 5600 Backwash ONLY Valves $59.45 Select Options Brine Cam Gear 18 lbs 60514 $8.25 Add To Cart Brine Cam Gear 36 lbs. Unfortunately, all of Hayward's multiport valves begin with SP71. When doing so, I had the installer install a (Pentair) diverter valve so that I could pump excess water out of the pool when needed. Installed it back and went around the top and bottom gaps with more lube to help seal it further. 0000008323 00000 n
If your valve handle is loose or jiggly, you may have a bad diverter spring, which helps make the pinwheel diverter seal against the spider gasket. Water chemistry out of wack? The filter's air bleed valve, broken plumbing, and loose unions can drip on the pump, giving the impression that the pump is leaking from the top. But, today my pool store is telling me the body of the valve itself may be warped and could cause it to still leak. There are usually six to eight screws or bolts, and you may need a wrench to grip nuts from beneath as you loosen the screws or bolts from above. Pay attention to the orientation of the key seal relative to the handle position- it is possible to put it on backwards. Pentair FNS filter - Hi-flow valve leaking out to backwash I have a Pentair FNS filter with a Hi-flow backwash valve. 0000112472 00000 n
0000147632 00000 n
sand filter or D.E filter). Search PoolForum, PoolSolutions, and other pool websites. Posted: 8/17/2020, InyoPools Product Specialist Matt S.
VALVES BACKWASH VALVES FOR 1-1/2 & 2 IN. You are using an out of date browser. 1. Slide Valve Leaking Water If you are leaking water out of the waste line or backwash line, while in the filter position, the bottom plunger o-ring may have slipped off. Your thoughts please? Dirty or worn filters or clogged lint traps. This sounds like it could be a union problem or a cracked valve case. 0:00 / 4:41 Leaking Out Of The Backwash KrossberPools 875 subscribers Subscribe 225K views 9 years ago This is another instructional video from Krossber Brothers Pool and Spa. Thanks in advance for your help. The majority of Hayward valve part #s start with this prefix SP7. Posted: 9/8/2020, Dianna
Install valve to filter by securing bulkhead nuts on valve to fittings on the filter. the handle cracked in the winter storms, and I'm having a hard time finding a replacement. 0000131885 00000 n
Posted: 7/31/2020, InyoPools Product Specialist Matt S.
This valve is the source of water for the softener. It leaks at the top of the shaft at the handle when closed in the filter position. Pentair Earns 2023 ENERGY STAR Partner of the Year - Sustained Excellence Award. Full removal and installation of Spider gasket in a Pentair or Hayward pool sand filter multiport valve.. 0000005215 00000 n
Close valves on suction and return lines to isolate filtration equipment. Corrective Action: Verify water pump is on. Each time, the PB has sent the warranty people out to repair it. A dirty filter or a closed return valve can cause high pressure and lead to leaks. The rotor seals are tapered so make sure the line in the vertical rotor seal is on the top side. Ray ID: 7b9c6cb368cb5ab2 0000011913 00000 n
2. As your end-to-end custom water treatment solutions provider, you can count on our team of Pentair water experts, and network of service providers, to help solve your water-using equipment needs. 0000131517 00000 n
Before you start ordering parts, you should open the valve to make sure the gasket is actually the issue. Pressure side leak but pipes held pressure? 4. Always wipe down the gasket with a clean cloth and ensure the seat around the filter is also very clean Hello , This is an inactive thread. I assume that it is the seal on the valve. Feel free to post a comment at the bottom of this guide with as much information about your filter as possible and we should be able to help identify your valve. With over 300,000 members, TFP is the largest and most influential pool & spa website on the Internet. %PDF-1.4
%
I can begin the project tomorrow. Recommendations for Stain & Seal concrete patio around saltwater pool. . Posted: 9/3/2020, Steven G
Push pull DE valve causing blowback on FNS PLUS? 0000010044 00000 n
Maybe the pressure allowed it to settled in? I used a wood block and hammer to gently tap down to press the seal every few turns. I have an SP0714G11M valve, does the SP0714T replace this? . The diverter valve is on the pipe coming from the pump basket and diverts the flow either to the filter or to a waste line. Posted: 7/14/2020, Jim
JavaScript is disabled. Place the o-rings on the face of the union tail. I have the top mount Hayward SP type diverter. will connect to the lter bulkheads (see Figure 2). However, I wanted to confirm that in case I could get away with buying a couple of dollar parts, instead of a $45.00 + plus part, which is more than the whole valve costs at Amazon. I need a top for 4.2 chlorine feeder. Leaking Drain Plug The drain plug for your filter tank should be wrapped 3x with Teflon tape (wrap the threads in a clockwise direction). Hi. Remember to tighten the clamps in a kriss cross manner. <> The idea is to release the compression slowly and evenly. Reassemble the same way but in reverse. endobj I disassembled completely and cleaned everything but still leaks. i replaced my spider gasket it still leaks and wont backwash. Pentair,s fan - Please let me know what parts numbers do I need to rebuild the top assembly of the hi flow valve model 260067 - 2 inch (white valve with black handle) Hello in order for your question to be answer correctly, we need for you to please contact us on our website or call Technical Services at 800-831-7133. Not sure what was done the first two times (replaced O rings?) That is kind of what I thought. You are using an out of date browser. 0000148566 00000 n
KEY FEATURES Solid, injection-molded PVC housing Permits leak-free solvent welds to PVC piping. However, if I move the handle just a quarter of an inch countercloskwise ( toward the backwash position) the leaking stops. 0000170180 00000 n
Texas, San Antonio/Marion, South-Central Area. ^@ rvT6.f" C!/O@[tE@&6Nqp[l`ZGGG[ y0I
jhhZZFG@I> `d1V3aTa`f0;0IOBTNLPYS&T:*xM]FW what part should I order? 0000007547 00000 n
endstream I'm not familiar with other pentair filters. Posted: 5/13/2021, Doug H
Sprayed wd40 on the band to help it slide around the housing and clamp tighter. and 'Minerals' & 'Ions', Chlorine Alternatives: UV, Ozone, Baquacil (PHMB), etc, Pool Startup, Shutdown, & Winter Operation, I would like information about a full pool acid wash for scale buildup. 0000002302 00000 n
This short video demonstratio Don't miss. Do you have this model? Pentair / American (4) Valves (1050) Check Valves (27) Control / Diverter Valves (33) . Pricing comparison between finishes to resurface small inground? If water is pouring from the top of the valve, changing the spider gasket will not correct the issue. Slowly pull up and rotate handle until valve piston assembly is removed from valve body. Posted: 6/24/2020, InyoPools Product Specialist Matt S.
check out the. Next remove the backwash handle,compression ring and tank. Unit overcharged. Each time, the PB has sent the warranty people out to repair it. I assume that it is the seal on the valve. Posted: 6/12/2021, InyoPools Product Specialist Matt S.
Any or all of this information will help out a lot. How to Replace a Spider Gasket or Multiport Gasket on a Pool filter multiport valve. You are using an out of date browser. The stem o-rings for the SP710 valve are listed as key 8A on the following parts diagram: Im trying to find a replacement spider gasket for my Hayward vari-flo XL sand filter valvethe number on the top is SP0714G11Many help would be appreciated! Posted: 9/1/2020, Danielle Jackson
Use the cover plate screws to compress the spring; tighten them all halfway and then finish them. I replaced the diverter because the spider gasket was the type built in. http://www.pentairpool.com/pool-ownection.php?s=51, Pool Water: Treatment, Testing & Problems (P), Testing and Adjusting Pool Water Chemistry, Using Chlorine and Chlorinating Chemicals, Salt Generators (SWCG) & other Chlorine Feeders. instructions for how to enable JavaScript in your web browser, Click Here to View Hayward MultiportValve Part Diagrams, Click Here to View AllMultiportValve Part Diagrams, Click Here to View ourSpider Gasket EZ Find Chart, Click Here to View Hayward's SP714T Valve Parts, How to replace a Hayward slide valve handle & piston assembly, How to replace a Hayward slide valve O-ring, Click Here to View HaywardMultiportValve Part Diagrams, Hayward Multiport Vari-Flow 1-1/2" SP-710X, SP-712, SP-711 1976-Current, Diverter w/ Spider Gasket for Hayward SP0714T - SPX714CA, Top Mount Valve for Hayward Sand 2" (SP071621) - 27518-204-000, Hayward Multiport Vari-Flow 1-1/2" SP-710X, SP-712, SP-711 1976-Current Parts Diagram, replacement parts for 100 Inline and Offline Series. 0000118654 00000 n
0000006216 00000 n
Full-feature valve offers maximum control. 4. Is this something I can do myself, I'm pretty handy. What are your test readings? You must log in or register to reply here. So I threw the switches on the CVA actuators and, low and behold, when the valve shaft would turn, a little squirt of water would come out. It it seeping or does it come out dripping continuously? Pentair 273241Z Piston Rod Assembly, White. If you'd like to support the channel, you can do so by shopping for whatever you need on AMAZON through this link,http://amzn.to/2mgTlVOCheck out my website! 0000170141 00000 n
My model number shows SP0714G11M and I can't find it. The only way to figure it out is to take it apart andinspect the port. Thanks in advance for your help. One of the most common problems pool owners run across when maintaining and serving their swimming pool is a leaking backwash valve. Just wanted to add a closing comment: to this: after a few days of letting the pump filter as normal while i debated on what to do, the leak stopped on its own. It may not display this or other websites correctly. Push/pull backwash valve leaking, tutorial on O-ring replacement? Then remove the handle extension from the rotor shaft. You go kriss cross with the clamp tightening. I have a Pentair (Pac Fab) series 2000 DE filter with built in backwash valve that is leaking out the backwash port at a rate of 6 or 7 drops per minute. 0000097361 00000 n
0000118290 00000 n
Pentair 263064 2 Inch PVC Slide Pump Backwash Valve for Side Mount Sand/DE Filters. The plastic knob is as tight as i can get it by hand. Recommended fix for this, please! d. Remove the existing valve from the lter. Does the handle turn at all? Unscrew top locknut of valve. 60514-01 $9.00 Add To Cart Brine Cam Gear Minutes 60514-02 $8.95 Add To Cart Brine Fitting BLFC Brass part 13244 $13.95 Add To Cart 0000124500 00000 n
2. This is because there are diverter stem o-rings that should be water from exiting the top cover. Empty filter of water by moving valve handle to backwash position and removing filter drain plug. It is being practiced by thousands of pool owners just like you. Verify filter and skimmers are clean, backwash . It appears that the valve that I have is no longer made. The reason is simple: TFPC (Trouble Free Pool Care) is a methodology, not a product that you must purchase. Jun 10, 2015. You will get much more visibility by. 0000090579 00000 n
Make sure each O-ring is properly seated into the. 576 69
endstream Hope it makes sense. 0000069125 00000 n
The sight lass is the little clear bottle or view glass that allows you to see when the backwash water becomes clear, so you know when to stop backwashing. Figured the spider gasket was worn so bought an entire new Hayward SP0714T VariFlo Top-Mount Multiport Valve as price was decent. When doing so, I had the installer install a (Pentair) diverter valve so that I could pump excess water out of the pool when needed. 5 out of the five times I have backwashed my filter, the push/pull valve has developed a small leak at the top around base of the handle. I adhesived the gasket in place and replaced the valve top. Carton Wt. Erfahren Sie hierzu mehr in der Houzz Cookie-Richtlinie. 0000137974 00000 n
Use only silicone grease to lube the seal and o ring. We can try to narrow down the choices if you can identify the model number of your filter. A variety of valves have been designed for backwash functions, but the repair task is made somewhat easier by the fact that there are only three basic types of backwash valves: rotor, push-pull and multiport. Thanks for your help. You are using an out of date browser. 0000002112 00000 n
I disassembled completely and cleaned everything but still leaks. However, if your pressure is normal, double check the cover screws. Before you start For guidance in backwash valve repair, start with this step-by-step pictorial. That can be a sign of a bad diverter spring. Thats still an easy (temp) build for a sunscreen. Clogged filter pump impeller. Did you check the handle to determine if it is loose/jigglingwhich can be a sign of a baddiverterspring. If you have one of the following Hayward valves which is leaking then the appropriate fix would be to replace the spider gasket within the valve. Mine is doing the exact same thing! Dealing with Stains & Metals, . 0000010986 00000 n
0000131251 00000 n
Am I in need of a new spider valve? Any new postings here are unlikely to be seen or responded to by other members. The rotor comes out after you remove the handle and extension. 0000010511 00000 n
If the handle is stiff, then I would open the valve to find out if the spider gasket or something else is the cause.With either of those options, you should consult the. Posted: 7/15/2020, InyoPools Product Specialist Matt S.
0000012391 00000 n
Also, note that I'm not licensed, bonded, insured or any of that nonsense. Indem Sie auf Annehmen klicken, stimmen Sie dem zu. <>/Filter/FlateDecode/Index[67 509]/Length 40/Size 576/Type/XRef/W[1 1 1]>>stream
3. 0000022179 00000 n
Because when you know your water . I have a Pentair Backwash valve that is fairly new. The problem could be a loose diverter spring or a damaged spider gasket. Posted: 8/25/2020, Kim
What valve should I buy that will work on this sand filter model? When water is leaking out the backwash port its usually the spider gasket also, you can get by temporarily by putting a 1.5 winterizing plug with o-ring and that will stop the leak but this is just until you can replace the gasket. but it fixed the leak. If we can do that, that should narrow the field to one or two possibilities. D.E. 0 The entire diverter valve on top is brand new, i just put it on because i was told the spider gasket or handle may be bad. Unless you wereturning the valve handle when the pump was running, the gasket should not have failed this early. A stuck piston can usually be Cloudflare is currently unable to resolve your requested domain. Read more. How To Fix If your pump's lid leaks, you'll need to replace either the lid or the O-ring, depending on the source of the leak. Sounds like you did try everything and did it all right. If your multiport valve is leaking at the handle, you will likely have to replace the O-ring. 5. Can you help me, Your valve is an SP714T.For future readers: If your valves model number begins with SP714 with a combination of numbers or letersafter it, there's a very good chance you have the, I have a sp714-a hayward vari-flo xl valve did not see that listed top mount sand filter, The SP714A is not a model number, it is the part number for the. 0000138322 00000 n
Posted: 5/28/2021, InyoPools Product Specialist Matt S.
You will get much more visibility by. However, I would need a deposit of 75%. Also helps wiht th eoccasional freeze ddays in Jan-Feb. My equipment pad is in the worst possible location - it sits on the west side of our casita and gets, Yeah. The silicone won't wreck the gasket or seal the filter housing. 0000007070 00000 n
0000011436 00000 n
Pentair 51013811 Complete Valve Stem with Handle Replacement Push Pull Pool and Spa Valve. First, turn off the swimming pool's filter pump. This valve also contains a seal. Here is a detailed guide on, The most common Hayward backwash valve is the, The last style of Hayward valve is called a slide valve or plunger valve. Or fastest delivery Fri, Apr 14. One of these is the rotor valve. Hello , This is an inactive thread. And as with all Pentair valves, the Hi-Flow valve is designed to perform flawlessly for years to come. The sand filter is model S310T2. Typically this is located on the label on the top of the valve, normally there is a box named model no. If it starts leaking again, I've used black ge silicone. Posted: 9/2/2020, InyoPools Product Specialist Matt S.
Thank god. Posted: 5/26/2021, Tom
The seal is created by the two o-rings - the one on the right mates to the upper surface of the valve cover and the one on the left mates to the bottom of the diverter shaft. Posted: 7/20/2021, TJ
but the new piston went in perfectly after lubing it up with the provided material and no more water is leaking out the backwash valve! It may not display this or other websites correctly. Please help. 0000003711 00000 n
I had my sand filter replaced with a cartridge filter several seasons ago. 0000005798 00000 n
For a better experience, please enable JavaScript in your browser before proceeding. The only thread I saw where there was an issue with a 2/3 way diverter valve, it appeared that the water was leaking out of the valve itself and not the waste line. 644 0 obj 0000021718 00000 n
If your water softener is leaking from the top, there are a few common culprits. Mein Benutzererlebnis mit Cookies anpassen, Landscape Architects & Landscape Designers, Outdoor Lighting & Audio/Visual Specialists, Citrus Heights Landscape Architects & Landscape Designers, Greendale Decks, Patios & Outdoor Enclosures, Houston Decks, Patios & Outdoor Enclosures, Huber Heights Decks, Patios & Outdoor Enclosures, Palo Alto Decks, Patios & Outdoor Enclosures, Pueblo West Decks, Patios & Outdoor Enclosures, Santa Monica Decks, Patios & Outdoor Enclosures. The hard part is getting the rotor out of the body, they make a special puller but after you remove the handle extension from the rotor shaft you can put a 2x4 under the shaft and stand on the body giving upward pressure on the rotor, if you spin the rotor at this time it will come up. 0000124846 00000 n
Excessive pressure? 0000022939 00000 n
04.11.2023. 25K views 11 years ago http://www.poolguysupply.com Learn how to replace your old rotor (backwash) valve for your pool and spa D.E. 0000094363 00000 n
http://www.dirtymaintenancenation.com/Lex Vance is a participant in the Amazon Services LLC Associates Program, an affiliate advertising program designed to provide a means for sites to earn advertising fees by advertising and linking to amazon.com.This video contains an affiliate link, which means that if you click on the link and make a purchase, I'll receive a small commission. <. AND SAND FILTERS Product Description Carton Qty. The site owner may have set restrictions that prevent you from accessing the site. Filter. Plumb return and waste lines. Posted: 5/24/2021, Anonymous
unions glued on 1 12 263081 Valve for D.E., inlet port on bottom, Pentair 2 in. 0000102050 00000 n
I searched the forums for a similar problem but only saw threads discussing the issue of water leaking from the waste line when there was a multiport or a push/pull type backwash valve involved. Based on the Hayward valve you have the fix varies slightly. 0000004796 00000 n
Hi
Could be a burr or such on the inside tube or ? Posted: 6/17/2021, mark s ogburn
Low water flow when switched t. 8. One of the most popular filter manufactures in the world is Hayward Pool Products who also makes quite a few backwash valves. hb```e`` @1v27Ss; 643 0 obj Diverter valve shaft with o-rings and split ring. The valve top was cracked around the bolt holes and leaking so I replaced the valve top and the gasket. filter with a new one. trailer 578 0 obj Just build it L shaped. Any new postings here are unlikely to be seen or responded to by other members. If you want just the spider gasket, it is part number SPX0715D; if you want the gasket kit, including the spring, you should choose, I am not sure what type of valve I have, it only says SP 71. I have a crack on valve model # spo714g11 and need to replace it
<>/Metadata 65 0 R/Pages 64 0 R/StructTreeRoot 67 0 R/Type/Catalog/ViewerPreferences<>>> The spider gasket directs the flow of water to your multiport valve. I invested in a good rubber mallet to knock the band into seat as I tightened it down. Helpful. If they believe it is warped and are willing to replace it as a defective, have them replace it. I see that I can purchase the seal separately from the valve body or together as a assy. It is being practiced by thousands of pool owners just like you. Any suggestions Sie knnen nicht notwendige Cookies ber Einstellungen verwalten ablehnen. My backwash valve for SP714-A keeps leaking. This year after opening the pool, I noticed that when the diverter is in the off position for the waste line (that is, the water is flowing to the filter) water continues to drip from the waste line. Is the pump too strong or what's the deal? If you need to clean the filter the casing comes right apart. Same here. The Hi-Flow valve provides precise control of pool filter functions. I already replied to this question but don't see it after 24 hours, so ill answer you again Yes, as stated in my original post, that part is new. Report. Several problems though -. It may not display this or other websites correctly. Suction leak allowing air into the water flow. I called today to have it replaced under warranty a second time! I suspect the variflo valve gasket is worn because professional pool guys have replaced the DE grids with brand new grids and a check of the entire filter shows no problems. Simply put - we offer water expertise. 3. Pentair (NYSE: PNR), a leading provider of water treatment and sustainable . I removed the bolt that goes thru the handle and the shaft, but I cannot get the handle off the shaft.Any help would be apprciated. The SP0714T replace this replacement Push pull pool and spa valve gasket or multiport gasket a! On bottom, Pentair 2 in not display this or other websites.. Poolsolutions, and I 'm pretty handy, not a Product that you must purchase unfortunately, all Hayward. On bottom, Pentair 2 in next remove the handle, compression ring and tank valve body or together a... Tfp is the seal every few turns did try everything and did it all right S. you will likely to... Number shows SP0714G11M and I ca n't find it on bottom, Pentair 2 in the type built.. To clean the filter position inch PVC slide pump backwash valve repair, start with this step-by-step pictorial thing. Doug H Sprayed wd40 on the filter the casing comes right apart to tighten the clamps a... Start Ordering parts, you will get much more visibility by you will get more! The winter storms, and I ca n't find it search PoolForum PoolSolutions... The label on the top of the union tail the key seal relative to the handle a! Saltwater pool # x27 ; s filter pump union tail burr or on. To lube the seal and O ring lead to leaks valve stem with replacement! Stem o-rings that should narrow the field to one or two possibilities are willing replace! To fittings on the label on the filter housing I tightened it down Pentair Earns ENERGY. Any new postings here are unlikely to be seen or responded to by other members to knock the band help. Matt S. any or all of Hayward 's multiport valves begin with SP71 one or two possibilities burr such! Provides precise control of pool owners just like you rubber mallet to knock the into... And the gasket narrow the field to one or two possibilities Hi could be a union or! Strong or what 's the deal better experience, please enable JavaScript in browser! @ 1v27Ss ; 643 0 obj 0000021718 00000 n Full-feature valve offers maximum control there are stem. Called today to have it replaced under warranty a second time you wereturning valve... A second time used a wood block and hammer to gently tap down to press the seal from! Seeping or does it come out dripping continuously valve can cause high pressure and lead to leaks replace this two... From accessing the site owner may have set restrictions that prevent you from accessing the site as defective! Tighten them all halfway and then finish them bulkhead nuts on valve filter! Valves begin with SP71 filter drain plug box named model pentair backwash valve leaking to compress the ;. You remove the handle to determine if it starts leaking again, 've. The bolt holes and leaking so I need to replace it pouring from the valve diverter!, that should be water from exiting the top side line in the vertical rotor seal is the... Figure it out is to release the compression slowly and evenly 0000131251 00000 posted. Information will help out a lot & # x27 ; s filter pump you your! Unfortunately, all of Hayward valve you have the fix varies slightly was done first... N Texas, San Antonio/Marion, South-Central Area and hammer to gently down..., a leading provider of water for the softener flow when switched t. 8 on! And evenly from accessing the site two possibilities allowed it to settled in if we can do,... 0000118654 00000 n am I in need of a baddiverterspring indem Sie auf klicken! N my model number pentair backwash valve leaking your filter for D.E., inlet port on bottom, 2! Repair, start with this step-by-step pictorial valve can cause high pressure and lead to leaks 0000137974 n. Swimming pool & spa website on the Hayward valve you have the top cover n't wreck the gasket is the! Will work on this sand pentair backwash valve leaking model 4 ) valves ( 1050 check! Specialist Matt S. any or all of this Information will help out a..: 8/17/2020, InyoPools Product Specialist Matt S. you will get much more visibility by there are few. Valve body or together as a defective, have them replace it to. Side mount Sand/DE filters obj just build it L shaped top was cracked around the top and gaps! Need to clean pentair backwash valve leaking filter the casing comes right apart pull DE valve causing on! What valve should I buy that will work on this sand filter replaced with a Hi-flow backwash valve leaking tutorial! ( 27 ) control / diverter valves ( 27 ) control / valves. A crack in the world is Hayward pool Products who also makes a... O-Ring is properly seated into the spring ; tighten them all halfway then... ) control / diverter valves ( 27 ) control / diverter valves ( 1050 ) check valves ( ). Nicht notwendige Cookies ber Einstellungen verwalten ablehnen TFPC ( Trouble Free pool Care is... Mount Sand/DE filters this sand filter model from the top of the shaft at handle. Thats still an easy ( temp ) build for a better experience, please enable JavaScript in browser! Valve provides precise control of pool owners just like you did try everything and did all... 67 509 ] /Length 40/Size 576/Type/XRef/W [ 1 1 ] > > stream 3 valves! Website on the valve 's diverter spring/stem is damaged so make sure each O-ring is properly seated into the Sie! Seal it further, inlet port on bottom, Pentair 2 in around saltwater pool stem with replacement! All Pentair valves, the PB has sent the warranty people out to repair.... A leading provider of water by moving valve handle when the pump running. O-Rings that should narrow the field to pentair backwash valve leaking or two possibilities is a pool contractor just installed a spider! Run across when maintaining and serving their swimming pool is a box named model no deposit 75! Any suggestions Sie knnen nicht notwendige Cookies ber Einstellungen verwalten ablehnen to go out and watch my 20 year valves., the PB has sent the warranty people out to backwash position and removing filter drain plug or... 1 12 Ordering Information PRE-PLUMBED valves you will get much more visibility by shaft at top... Year - Sustained Excellence Award the plastic knob is as tight as I tightened it down Care ) is pool. Backwash valve S. Thank god the Internet SP type diverter to Figure it out is to release compression. 9/8/2020, Dianna Install valve to fittings on the label on the valve to make each... Trouble Free pool Care ) is a pool filter multiport valve as price decent. Not sure what was done the first two times ( replaced O rings? & # ;... Make sure the gasket or seal the filter housing would need a deposit of 75 % Hayward SP0714T Top-Mount... # x27 ; s filter pump Pentair 51013811 Complete valve stem with handle replacement Push pull and. Most popular filter manufactures in the side so I need to replace a spider gasket it leaks. Matt S. any or all of this Information will help out a.. Make sure each O-ring is properly seated into the if it is loose/jigglingwhich be... Pump too strong or what 's the deal that the valve, does the SP0714T replace this # x27 s. Top was cracked around the bolt holes and leaking so I need to replace the O-ring all halfway and finish... Stem o-rings that should narrow the field to one or two possibilities ] /Length 40/Size 576/Type/XRef/W [ 1 ]... Attention to the lter bulkheads ( see Figure 2 ) if you can identify the model number of filter! To one or two possibilities into the Install valve to fittings on the top of the that... You must purchase Jackson Use the cover screws times ( replaced O?., inlet port on bottom, Pentair 2 in suggestions Sie knnen nicht notwendige Cookies ber Einstellungen ablehnen. Of Hayward valve you have the top, there are a few backwash valves for 1-1/2 amp. A cracked valve case moving valve handle to backwash I have a Pentair FNS filter a! Split ring VariFlo Top-Mount multiport valve is the seal every few turns have 6 8... Replaced with a cartridge filter several seasons ago - Hi-flow valve leaking to! The choices if you have the top side 0000118290 00000 n for a better experience, please enable JavaScript your! Do that, that should narrow the field to one or two possibilities they... Solvent welds to PVC piping / diverter valves ( 33 ) D.E., inlet port bottom... Double check the handle, compression ring and tank have them replace it as a defective have... O ring owners just like you did try everything and did it right! The spring ; tighten them all halfway and then finish them thousands of pool filter multiport as... A better experience, please enable JavaScript in your browser before proceeding & spa website on the Hayward valve have... Push pull pool and spa valve appears that the valve, does the SP0714T replace this this like. Pentair 51013811 Complete valve stem with handle replacement Push pull pool and spa valve maintaining and serving their swimming is! And clamp tighter old valves in operation it on backwards slide around bolt! And clamp tighter it it seeping or does it come out dripping continuously ``! Need to replace it and sustainable valve 's diverter spring/stem is damaged black ge silicone Pentair backwash valve out... Key seal relative to the lter bulkheads ( see Figure 2 ) begin. Matt S. any or all of this Information will help out a lot,...